HomeProductsDC EV Charging Stations960kW Split Type DC Charging Station Combined By One Power Cabinet Plus Multiple Charging Terminals

Share:

960kW Split Type DC Charging Station Combined By One Power Cabinet Plus Multiple Charging Terminals

  • 360-960kW
  • CCS2 and GB/T
  • 6-16 Connectors

Product Features

  • Power Modules and System Configuration
    Supports scalable architecture for high power EV charging stations, ranging form 360kW to 960kW DC charging station systems.
  • Multi-Interface Compatibility
    Designed for split type DC EV charging stations to accommodate diverse connector standards.
  • Intelligent Power Allocation
    Features dynamic load balancing ideal for commercial EV charging stations and split charger networks.
  • User-Friendly Appearance and Operational Design
    Clean interface and modular exterior suitable for split EV charger deployments.
  • High-Performance Output
    Delivers robust power scaling up to 960kW DC charging station outputs.
  • International Certification Support
    Complies with global standards, backed by leading EV charger manufacturers in China.

Product Description

To achieve maximum uptime, Anari’s Split DC fast charging station combines remote diagnostics with proactive monitoring, ensuring reliable performance for every charge. The system also offers scalable power—easily expanding from small fleets to large hubs with its 480kW architecture, while multiple connectors and a split EV charger design enable flexible deployment. Building on this, the smart energy management system intelligently balances loads, reducing energy costs and maintaining stable performance even in high-demand environments. All of this is backed by trusted manufacturing: Anari Energy, a leading EV charger manufacturer in China, designs split-type DC fast charging stations for long-term reliability. Its portfolio of 360kW to 960kW DC chargers meets international certifications and global quality standards. Driven by manufacturing excellence, Anari Energy continues to innovate in split DC fast charging stations and high-power EV chargers, supporting the worldwide adoption of electric vehicles.

Specifications

Basic Specification Model Fora Series
Charging Mode CCS2 & GB/T
Rated Power 360/480/600/720/960KW
Max Connectors (Air-Cooling Terminal) 6/8/10/12/16
Cooling Forced Air-cooling/liquid cooling
Dimensions(W*D*H) 1950* 1650* 770mm(H*W*D)
Weight 820/870/950/1010/1100Kg
Packaging Dimensions 2170*1840*1140(H*W*D)
Input Input Voltage 400±15%
Frequency 50/60Hz
Power Factor ≥0.99
Peak Efficiency ≥95%
Output Output Voltage Range 200~1000VDC
Constant power Voltage 300~1000VDC
Peak Efficiency ≥95%
Margin of Voltage Error ≤±0.5%
Margin of Current Error ≤±1%
Stable Voltage Accuracy ≤±0.5% 
Stable Current Accuracy ≤±1%
Peak of the Ripple ≤±1%
Environment Operation Temperature -20℃~+50℃(Use at a reduced frequency above 50℃)
Storage Temperature -40℃~+70℃
Humidity ≤95%RH, No Condensation
  Items Terminal
Basic Specification Model Fora-L Fora-A
Rated Output Power(kw) 600 250
Max Connectors 1 2
Cooling Liquid-Cooling Air-Cooling
Dimensions(W*D*H) 1650*500*369mm(W*H*D) 1450*500*219(H*W*D)
Packaging Dimensions 1800*720*440mm(W*H*D) 1650*720*420(H*W*D)
Output Output Voltage Range 200~1000VDC
Constant Power Voltage 300~1000VDC
Current Range per Gun 0~600A 0~250A
Peak Efficiency ≥95%
Margin of Voltage Error ≤0.5%
Margin of Current Error ≥30Ah,≤+1%;<30Ah,≤±0.3A
Stable Voltage Accuracy ≤0.5%
Stable Current Accuracy ≤1%
Peak of the Ripple ≤1%
Cable Length 5m
Start Way QR/VIN/RFID
Environment Operation Temperature -20℃~55℃
Storage Temperature -40℃~75℃
Application Site IP54
Humidity 5~95%RH, non-condensing
Working Altitude less than 2000m

FAQ

  • Q: What is the biggest feature of this Split DC Charging Station?

    A: Anari Energy's Split DC Charging Station has the following three prominent features:
    - Multi-power segment coverage (360kW - 960kW): Supports flexible configuration to meet high-power rapid energy replenishment needs in different scenarios.
    - Intelligent Power Distribution and Efficient Heat Dissipation: Adopting modular design to achieve intelligent dynamic load balance and ensure all-weather efficient operation.
    - Internationalization Certification and Multi-Interface Compatibility Support: Multiple protocols such as CCS2 and GB/T, compliant with international standards, and adaptable to mainstream vehicle models worldwide.

  • Q: Compared to the Integrated Charging Station, what are the advantages of the Split DC Charging Station?

    A: Compared with Integrated Charging stations, Split DC Charging Stations have a more flexible layout in structural design, with the main unit separated from multiple terminals; power distribution features dynamic power sharing, allowing for flexible adjustment according to demand; space utilization is optimized as the terminals are compact and do not take up much space, greatly saving parking space; expansion capability only requires adding terminals, with low expansion costs and fast speed; they are suitable for public stations with high power demand and large traffic flow.

  • Q: What payment methods does this charging pile support?

    A: This Split DC Charging Station supports 3 payment methods:

    - RFID Payment: The RFID cards of charging station operators are settled and paid according to the actual charging electricity; RFID cards with end-user stored value are settled and paid according to the actual charging electricity.
    - OCPP Platform Payment: Payment is made through the OCPP platform that integrates multiple payment methods.
    - POS payment: Pay by credit card based on actual electricity consumption.

  • Q: Where is this Split DC Charging Station suitable for installation?

    A: Anari Energy's Split DC Charging Station has a wide range of applications, suitable for highway service areas, bus charging stations, airport charging stations, commercial parking lots, etc., meeting the needs of various scenarios.

  • Q: What are the innovative points of this Split DC Charging Station in terms of protection?

    A: Anari Energy's Split DC Charging Station adopts the industry standard protection level IP54, is not afraid of dust and rain, and can be used safely in outdoor environments. Meanwhile, it also has 10 major intelligent protection functions: lightning protection, short-circuit protection, overload protection, overcurrent protection, overvoltage protection, overcharge protection, leakage protection, over temperature protection, chip protection, and waterproof and dustproof.

  • Q: What is the main unit power and terminal configuration of this Split DC Charging Station?

    A: The main unit of Anari Energy's Split DC Charging Station has a rated power of 360 - 960kW, and is intelligently equipped with 1 liquid-cooled terminal and 2 - 7 air-cooled terminals in terms of terminal configuration. For example, with a rated power of 600kW, 1 liquid-cooled terminal and 4 air-cooled terminals can be optionally configured, and the power of each terminal will be dynamically adjusted and distributed according to actual usage requirements.

WhatsApp